Since you've taken the time to find
this, I bet you can start your air conditioner in 10 steps yourself.
First off let me dispense of a myth.
Every spring I am asked to recharge the refrigerant in my friend’s air
conditioners. Truth be told, refrigerant in a closed clean system it will not
breakdown, unless a leak develops on one of the copper lines or fittings.
The refrigerant should never require any maintenance.
In some cases regularly checking the
refrigerant can add contaminates to the system and reduce the life of your unit.
The following steps do not include opening refrigerant lines. That job is best
left to a qualified technician.
Please read this document completely before starting.
Should you not feel comfortable in doing any part of this
procedure, call a qualified technician.
Ok let’s get started.
1-Turn the power off to both your furnace and air conditioner. Some of
the steps we will be discussing are dangerous if power is present. For the
furnace and the air conditioner there should be separate breakers in your
electrical panel that you will shut off.
2-Remove the front door of the furnace and vacuum out the enclosure, as
well as clean out any debris that may be in the fan housing, then replace
the filter with a new one.
3-Give the fan blade a spin and listen for a rumbling sound and check
if the fan is spinning freely. This is an indication that you may have a
possible bearing problem. If oil ports are present on the motor or bearings,
put a few drops of non detergent oil in them. Then close up the furnace and
head outside.
Note: If you think there is a bearing problem it
should be looked after soon. If you want to try to change the motor yourself
and need some help, try to describe problem
and post your question. See step 10.
If you do not want to attempt the work. Call a qualified technician.
4-(Remember,
Power off) Remove the access door from the outdoor unit and clean any debris
from it as well as those cobwebs and nests that tend to accumulate around
the electrical relays, also note any damaged wiring.
5-Apply a cleaning agent like a medium strength household cleaner
(using a spray bottle), to the outdoor
coil, then wash it off with your garden hose. When cleaning the coil
make sure to use enough water pressure that you can see the water spray
completely through the coil but not enough pressure that you may damage it.
6- Just like with your furnace give the fan blade a spin and make sure
it sounds smooth, also check for any hair line cracks in the blade or any
play (Looseness) in the pop rivets holding it together. If an oil port is
present on the motor add a few drops of non detergent oil into them.
When that is all complete, close the unit up and restore the power to it as
well as the furnace.
7-To perform this step you should try to wait until the outside air
temperature in the mid to high 70’s (21 deg C). This will allow the system
to be running near its peak operating pressure.
Ok let’s turn it on.
While
the unit is running,
have a walk around the furnace inside as well as the air
conditioner outside. Listen for sounds you may not
have noticed before. When you’re satisfied that everything seems ok, let it
run for 15 minutes.
If
for some reason you do hear any unusual noises, or problems you may
encounter, try to describe problem and post your question.
See step 10.
8-While were letting it run, have a look at the vents in the whole
house and make sure all they are all open. We have a tendency to shut off
some vents to try to get the air to the upper levels in our home. Too much
restriction in the ductwork is hard on the air conditioner. Closing a few
vents is ok but, it’s good to start the year off clean. I recommend reducing
the amount of air into the basement, but nowhere else. If you are having
problems with cooling the 2nd floor, it’s more than likely the
problem is with the location of the return air grill on the 2nd
floor and not the amount of cool air entering the space. If you need
more advice on air balancing. See step 10.
9-Head outside and let’s see how the unit is operating. The first thing
you should notice is that the air blowing off the unit should be warm. Next,
look for the 2 copper lines exiting the unit, one will be small, the other
larger line, is most likely covered in a black insulation.
This
small line is called the liquid line. The temperature of this line should be
neutral to warm to the touch. The larger one may need a bit of insulation
removed to check it; this one should be cool to cold, not cold like an ice
cube, but cool enough that you feel it. Normally its temperature is in the
50˚-55˚(10-12 deg C) area. If you are unsure and need some advice See step 10.
While
you are checking temperatures, one other thing you can check is the temperature
difference across the furnace. Meaning, the difference between the incoming
and out going air.
Back into the house we go
Place a
thermometer in or at the return air grill and take a temperature reading,
then do the same thing a at the supply air grill. Subtract the difference in your temperature readings.
This number should be in the area of 15˚ (9.5°C)
if is not See step
10.
That’s
it your all done.
10 - If you require further information like a more detailed explanation
of any of the above steps. You can register as a user by clicking at this
link
http://www.hvacmechanic.com/forums/forum-register.htm then you can post
us a message in our forums at
http://www.hvacmechanic.com/forums/forums.htm. This is a free service.
Should you have any questions at any time about any part of your air
conditioning, furnace, ventilation, humidification, or you need advice on
some work you had quoted by a contractor. Post questions in the
forums